Commit Graph

9 Commits

Author SHA1 Message Date
John Spray
67ad420e26 tests: turn down error rate in test_compute_pageserver_connection_stress (#12721)
## Problem

Compute retries are finite (e.g. 5x in a basebackup) -- with a 50%
failure rate we have pretty good chance of exceeding that and the test
failing.

Fixes: https://databricks.atlassian.net/browse/LKB-2278

## Summary of changes

- Turn connection error rate down to 20%

Co-authored-by: John Spray <john.spray@databricks.com>
2025-07-24 14:42:39 +00:00
Alexander Bayandin
30a7dd630c ruff: enable TC — flake8-type-checking (#11368)
## Problem

`TYPE_CHECKING` is used inconsistently across Python tests.

## Summary of changes
- Update `ruff`: 0.7.0 -> 0.11.2
- Enable TC (flake8-type-checking):
https://docs.astral.sh/ruff/rules/#flake8-type-checking-tc
- (auto)fix all new issues
2025-03-30 18:58:33 +00:00
Heikki Linnakangas
565a9e62a1 compute: Disconnect if no response to a pageserver request is received (#10882)
We've seen some cases in production where a compute doesn't get a
response to a pageserver request for several minutes, or even more. We
haven't found the root cause for that yet, but whatever the reason is,
it seems overly optimistic to think that if the pageserver hasn't
responded for 2 minutes, we'd get a response if we just wait patiently a
little longer. More likely, the pageserver is dead or there's some kind
of a network glitch so that the TCP connection is dead, or at least
stuck for a long time. Either way, it's better to disconnect and
reconnect. I set the default timeout to 2 minutes, which should be
enough for any GetPage request under normal circumstances, even if the
pageserver has to download several layer files from remote storage.

Make the disconnect timeout configurable. Also make the "log interval",
after which we print a message to the log configurable, so that if you
change the disconnect timeout, you can set the log timeout
correspondingly. The default log interval is still 10 s. The new GUCs
are called "neon.pageserver_response_log_timeout" and
"neon.pageserver_response_disconnect_timeout".

Includes a basic test for the log and disconnect timeouts.

Implements issue #10857
2025-02-24 20:16:37 +00:00
Tristan Partin
5bd8e2363a Enable all pyupgrade checks in ruff
This will help to keep us from using deprecated Python features going
forward.

Signed-off-by: Tristan Partin <tristan@neon.tech>
2024-10-08 14:32:26 -05:00
Heikki Linnakangas
19db9e9aad tests: Replace direct calls to neon_cli with wrappers in NeonEnv (#9195)
Add wrappers for a few commands that didn't have them before. Move the
logic to generate tenant and timeline IDs from NeonCli to the callers,
so that NeonCli is more purely just a type-safe wrapper around
'neon_local'.
2024-10-03 22:03:22 +03:00
Joonas Koivunen
05dd1ae9e0 fix: drain completed page_service connections (#8632)
We've noticed increased memory usage with the latest release. Drain the
joinset of `page_service` connection handlers to avoid leaking them
until shutdown. An alternative would be to use a TaskTracker.
TaskTracker was not discussed in original PR #8339 review, so not hot
fixing it in here either.
2024-08-07 17:14:45 +00:00
Sasha Krassovsky
d43d77389e Add retry loops and bump test timeout in test_pageserver_connection_stress (#7281) 2024-05-01 21:36:50 -07:00
Sasha Krassovsky
be30388901 Add retry to fetching basebackup (#6537)
## Problem
Currently we have no retry mechanism for fetching basebackup. If there's
an unstable connection, starting compute will just fail.

## Summary of changes
Adds an exponential backoff with 7 retries to get the basebackup.
2024-02-01 20:50:04 +00:00
Sasha Krassovsky
87389bc933 Add test simulating bad connection between pageserver and compute (#5728)
## Problem
We have a funny 3-day timeout for connections between the compute and
pageserver. We want to get rid of it, so to do that we need to make sure
the compute is resilient to connection failures.

Closes: https://github.com/neondatabase/neon/issues/5518

## Summary of changes
This test makes the pageserver randomly drop the connection if the
failpoint is enabled, and ensures we can keep querying the pageserver.

This PR also reduces the default timeout to 10 minutes from 3 days.
2023-11-08 19:48:57 +00:00