* perf(windows): read the process table natively instead of forking PowerShell Seven independent readers each forked powershell.exe to run Get-CimInstance Win32_Process, with a wmic fallback that Windows 11 24H2 has removed. On a domain-joined host with PowerShell Transcription enabled by policy, one of them running every ~2s recorded ~289GB across 1.4 million files (#15209). The same scan cost ~700ms and ran per pane (#15036), and a Group Policy or AV block turned it into 'unavailable', which callers read as 'no evidence' -- which is how a PTY tree survives its own teardown (#9045, #10475). A Toolhelp32 snapshot answers the same question with no child process. Measured on Windows 11 with 1050 processes, p50/p95: pid+ppid+name 15.9 / 17.5 ms +memory +command line 30.6 / 33.7 ms Get-CimInstance 706 / 723 ms Two upstream defects needed patching, both found by running it on real hardware. The binding requires Spectre-mitigated libraries our agents do not carry (node-pty is patched the same way). And enumeration stopped after 1024 processes: on a host with 1051 the module returned exactly 1024, and the querying process was itself among the 27 missing -- a truncated snapshot silently hides the descendants teardown is looking for, which is the failure this whole change exists to remove. Migrated: the foreground/descendant reader (the #15209 scraper and the teardown identity gate) and the port scanner's PID attribution. NOT migrated: the memory collector and three identity probes, which need Win32_Process.CreationDate and have no native equivalent. Start time is a proxy for identity anyway; an inherited job handle is the real answer, so those belong with the job-object work rather than here. Packaging follows the windows-native-registry contract exactly: optional, absent from onlyBuiltDependencies so macOS/Linux never run node-gyp, win32-only in the packaged runtime. Asserted by the existing contract test, which also stops pinning a whole source literal that only tested its own formatting. * chore(process): ratchet the child_process allowlist down windows-foreground-process-rows.ts no longer spawns anything, so its allowlist line is stale. The guard fails on a stale entry as well as a new one, precisely so a migrated file cannot keep a slot open and hide the next regression in the same path. * fix(ports): import the process-table reader the scanner uses Missing import: the migration replaced the PowerShell call but the new symbol was never imported, so tsc failed. Vitest transpiles without typechecking, which is why the port-scanner suite stayed green. * fix(deps): sync this branch's lockfile with its patch set Same class as the fix on the tip branch: pnpm records a hash per patched dependency, and this branch introduces the windows-process-tree patch without its lockfile entry matching. Every job here failed at install with ERR_PNPM_LOCKFILE_CONFIG_MISMATCH. Verified with --frozen-lockfile, which is what CI runs and what my local runs were not. * test(relay): drive the relay's Windows fixtures from the native snapshot Two relay cases fed a PowerShell CIM payload through a mocked execFile. That reader is gone, so both failed -- deterministically, on every PR run for this branch and the one above it. I did not catch it because my own verification sweep was 'src/main src/shared config/scripts' and never included src/relay. The relay is a first-class consumer of the process table; leaving it out of the sweep is how a deterministic failure survived six review rounds.
7.0 KiB
Design System
All UI work — layout, color, typography, spacing, component selection, UX behavior — must follow docs/STYLEGUIDE.md. Use the tokens defined in src/renderer/src/assets/main.css (the canonical source) and the shadcn primitives in src/renderer/src/components/ui/. Don't invent new color values, font sizes, or shadow tiers when a documented one already covers the role. When STYLEGUIDE.md is silent, follow the resolution order in its final section.
Electron UI Validation
Use the $electron skill and Playwright CDP for rendered Orca UI checks. Do not use computer-use for Orca UI validation.
Style
Concise/Brief Non-obviosu comments ONLY
- DO NOT: be verbose, explain the obvious, walk through the code ("WHY not HOW")
- BE CONCISE. 1 LINE if possible
Lint Rules: Do Not Disable Max Lines
NEVER add a max-lines disable (eslint-disable max-lines, oxlint-disable max-lines, or line-specific variants), and never add a per-file max-lines bump in mobile/.oxlintrc.json.
File and Module Naming
Never use vague names like helpers, utils, common, misc, or shared-stuff for files, folders, or modules. They carry zero info and tend to become dumping grounds. Name files after what they actually contain — prefer the concrete domain concept (e.g. tab-group-state.ts, terminal-orphan-cleanup.ts) over the generic role (tabs-helpers.ts, terminal-utils.ts). If you find yourself reaching for helpers, the file probably has more than one responsibility and should be split, or there's a better name hiding in the code that describes what the functions operate on.
Type Declarations: Prefer .ts Over .d.ts
Considerations
Worktree Safety
Always use the primary working directory (the worktree) for all file reads and edits. Never follow absolute paths from subagent results that point to the main repo.
Cross-Platform Support
Orca targets macOS, Linux, and Windows. Keep all platform-dependent behavior behind runtime checks:
- Keyboard shortcuts: Never hardcode
e.metaKey. Use a platform check (navigator.userAgent.includes('Mac')) to pickmetaKeyon Mac andctrlKeyon Linux/Windows. Electron menu accelerators should useCmdOrCtrl. - Shortcut labels in UI: Display
⌘/⇧on Mac andCtrl+/Shift+on other platforms. - File paths: Use
path.joinor Electron/Node path utilities — never assume/or\. - Windows setup scripts: the setup/issue-command runner is a
.cmdbatch file unless the script starts with a#!line — never derive that from the user's terminal-shell preference, and never launch a.cmdrunner with a barecmd.exe /cfrom a Git Bash pane (MSYS rewrites the/c). Seedocs/reference/windows-setup-shell.md. - Windows child processes: start them through
runProcess/spawnProcessinsrc/shared/child-process/— neverchild_processdirectly. It pinswindowsHide, refusesshell: true, and encodes.cmd/.batarguments so neitherCommandLineToArgvWnorcmd.exemangles them. A ratchet test fails on any new direct import. - Windows process enumeration: read the table through
src/main/windows/windows-process-table.ts, never by forkingpowershell.exe. Seedocs/reference/windows-process-enumeration.md. - WSL commands: build argv with
buildWslExecArgs(always--exec— under--,wsl.exeexpands$namein every argument and silently rewrites the script), and fence anything whose stdout you parse withbuildWslCapturedLoginShellCommand, because the interactive login shell prints the distro banner to stdout. Seedocs/reference/wsl-command-execution.md. - Linux native modules: keep the glibc floor at Ubuntu 20.04 / glibc 2.31. A module compiled from source on a newer runner can reference symbol versions absent on the floor and crash the app on startup. See
docs/reference/linux-glibc-compatibility.md; packaging fails if a bundled native binary needs newer glibc.
SSH Use Case
All changes must consider the SSH use case. Don't assume local-only execution. Before changing anything that reports on, stops, or lists remote work, follow docs/reference/ssh-execution-boundary.md: the execution host owns everything that touches execution, and loss of contact is never evidence of process death — the verdict vocabulary is live / unverifiable / exited, with no synonyms.
Folder Workspace Use Case
All changes must consider folder workspaces as well as git worktrees. Don't assume every workspace is a git worktree.
Remote Wire Compatibility
Clients and remote Orca servers update independently, so mixed versions are the normal state. Before changing anything a paired client and host exchange — RPC params, stream frames, or the content either side publishes over them — follow docs/reference/remote-wire-compatibility.md. A new optional field is safe; a new stream opcode must be capability-negotiated because decoders drop unknown opcodes silently; and changing what the host publishes reaches old clients even with no wire change.
Git Binary Compatibility
Orca runs the user's Git binary on native, WSL, and SSH hosts, which may all have different versions. Treat Git 2.25 as the core-workflow baseline and follow docs/reference/git-compatibility.md.
When adding or changing a Git command:
- Check when every subcommand and option was introduced. For newer behavior, keep a baseline-compatible fallback or degrade safely.
- Use
GitCapabilityCachewith a narrow unsupported-error predicate so recurring operations do not retry a known-invalid command. Do not rely only ongit --version; wrappers such assimple-gitdo not remove host-version differences. - Scope capability state to the host that executes Git: native, WSL distro, SSH provider, or relay connection. Cover the first fallback, later cached calls, concurrent probes, and relevant host isolation in tests.
- Keep the real-binary compatibility contract in PR CI current. When adopting a newer Git feature, add its version boundary so the preferred command and fallback both run against representative Git releases.
- Preserve commands that begin with global Git options such as
-cbefore the subcommand, including auto-maintenance suppression used by worktree-create fetches.
Git Provider Compatibility
Source-control and review changes must consider GitLab and other supported git providers, not only GitHub. Keep provider-specific behavior behind explicit checks, and avoid GitHub-only naming for generic review concepts.
GitHub CLI Usage
Be mindful of the user's gh CLI API rate limit — batch requests where possible and avoid unnecessary calls. All code, commands, and scripts must be compatible with macOS, Linux, and Windows.