Files
orca/.github/workflows/win-orcad-serve-switch-e2e.yml
T
Jinwoo Hong 776c791554 feat(orcad): ship the mobile web page so phones paired to orcad get it (#29882)
* feat(orcad): ship the mobile web page so phones paired to orcad get it

orcad never carried out/mobile-web, so it did not advertise
mobileWeb.bundle.v1 and phones paired directly to an orcad server fell
back to the app's built-in native screens.

The built page now ships in every orcad package at out/mobile-web, the
path getBundledMobileWebBundleRoot already probes under the install
root. Its manifest is a fixed artifact; its content-addressed assets
join the hashed artifact list from that manifest, as one shared copy in
the template's common files. build-orcad fails when the page is missing
or stale, and CI lanes that build orcad now build the page first.

* ci(orcad): check out mobile/ for the Windows host template build

* refactor(orcad): copy the page tree whole and build it once per CI run

The guard already refuses unlisted files, so staging copies the
bundle directory as native-chat-visuals is copied. The shipped template
takes the page the qualification lanes tested, the e2e build artifact
carries it, and the PR smoke builds it through install-mobile-dependencies
behind its own scope step. Drops tests that duplicated the guard's own.

* fix(orcad): refuse a template page asset name that escapes the slot
2026-10-16 19:29:41 -07:00

128 lines
5.0 KiB
YAML

name: Windows packaged orcad serve switch E2E
# Why: proves D7 on a real Windows install. The installed desktop app forks its terminal daemon
# from the relocated %LOCALAPPDATA%\Orca\daemon-host; `orca serve` then serves the same profile
# on orcad and must adopt that daemon, and the desktop must reattach the terminal afterwards and
# still write its settings under orcad's data-root ACL. Unpackaged e2e cannot exercise the
# relocation, which only packaged builds do. A CI runner is the only safe place to install.
on:
pull_request:
types: [opened, synchronize, reopened, ready_for_review, converted_to_draft]
paths:
- 'src/main/daemon/**'
- '!src/main/daemon/**/*.test.ts'
- '!src/main/daemon/serialize-grid-roundtrip.ts'
- '!src/main/daemon/mock-descendant-sweep.ts'
- '!src/main/daemon/daemon-host-relocation.test-fixture.ts'
- '!src/main/daemon/daemon-endpoint-reachability-test-harness.ts'
# D7 packages production entries; the unit jobs own these test roots.
- 'src/main/orcad/**'
- '!src/main/orcad/**/*.test.ts'
- 'src/cli/runtime/**'
- '!src/cli/runtime/**/*.test.ts'
- 'src/shared/orcad-local-serve-selection.ts'
- 'tests/tools/win-update-e2e/**'
- '.github/workflows/win-orcad-serve-switch-e2e.yml'
workflow_dispatch:
permissions:
contents: read
concurrency:
group: win-orcad-serve-switch-e2e-${{ github.event.pull_request.number || github.ref }}
cancel-in-progress: true
jobs:
serve-switch:
name: packaged Windows Electron/orcad serve switch (D7)
if: github.event_name != 'pull_request' || github.event.pull_request.draft != true
runs-on: windows-2022
timeout-minutes: 75
env:
NODE_OPTIONS: --max-old-space-size=4096
ORCA_BACKGROUND_LAUNCH: '1'
steps:
- name: Checkout
uses: actions/checkout@v6
with:
persist-credentials: false
- uses: ./.github/actions/install-node-dependencies
with:
native-runtime: node
# Same key inputs as win-update-survival-e2e: a harness-only edit skips the installer build.
- name: Cache branch installer
id: cache-installer
uses: actions/cache/restore@v4
with:
path: dist/orca-windows-setup.exe
key: serve-switch-installer-v2-${{ hashFiles('src/**', 'config/**', 'native/**', 'resources/**', 'mobile/**', 'patches/**', 'package.json', 'pnpm-lock.yaml', 'pnpm-workspace.yaml') }}
- uses: ./.github/actions/install-mobile-dependencies
if: steps.cache-installer.outputs.cache-hit != 'true'
- uses: ./.github/actions/prepare-windows-agent-hook
if: steps.cache-installer.outputs.cache-hit != 'true'
- uses: oven-sh/setup-bun@0c5077e51419868618aeaa5fe8019c62421857d6 # v2.2.0
if: steps.cache-installer.outputs.cache-hit != 'true'
with:
bun-version-file: config/.bun-version
# Before the template exists: packaging verifies a present template for every target.
- name: Build Windows installer (unsigned)
if: steps.cache-installer.outputs.cache-hit != 'true'
shell: bash
env:
ORCA_REUSE_PREPARED_NATIVE_RUNTIME: '1'
run: |
node config/scripts/ensure-native-runtime.mjs --runtime=electron
pnpm run build:desktop:ci
pnpm exec electron-builder --config config/electron-builder.config.cjs --win --publish never
- name: Cache the built installer
if: steps.cache-installer.outputs.cache-hit != 'true'
uses: actions/cache/save@v4
with:
path: dist/orca-windows-setup.exe
key: ${{ steps.cache-installer.outputs.cache-primary-key }}
# The win32-x64 template the harness drops into the install, which is where serve looks.
- uses: ./.github/actions/prepare-orcad-prebuilds
with:
resolve-windows-cache: 'true'
restore-windows-cache: 'true'
- uses: ./.github/actions/prepare-windows-cli-launcher
with:
arches: x64
- uses: ./.github/actions/build-mobile-web-bundle
- name: Build the win32-x64 orcad template
shell: bash
env:
ORCA_REUSE_PREPARED_WINDOWS_SECURITY: 'true'
run: |
node config/scripts/ensure-native-runtime.mjs --runtime=node
node config/scripts/build-windows-process-tree-addon.mjs --arch=x64 --reuse-prepared-runtime
node config/scripts/build-orcad-template.mjs --targets win32-x64
- name: Switch serve hosts on the installed app's profile
shell: bash
run: |
mkdir -p artifacts
node tests/tools/win-update-e2e/serve-switch.mjs \
--installer dist/orca-windows-setup.exe \
--template out/orcad-template 2>&1 | tee artifacts/serve-switch.log
exit "${PIPESTATUS[0]}"
- name: Upload serve switch output
if: always()
uses: actions/upload-artifact@v7
with:
name: win-orcad-serve-switch-output
path: artifacts/
retention-days: 7
if-no-files-found: warn