Neil 6a9ae3804d fix(windows): stop a winpty pty id from matching a ConPTY job
winpty.cc and conpty.cc each mint their 'pty' id from an independent
counter, and windowsPtyAgent stores both in the same _pty field. So a
winpty-backed terminal's id can collide with a live ConPTY baton -- and
closing that pane would have terminated an unrelated pane's entire
process tree.

Both job entry points now take the shell pid and the native side refuses
unless GetProcessId(hShell) matches, which makes the id unforgeable.

Two more from the same read-through:
- ResumeThread's failure was ignored. A shell left suspended is a pane
  that never prints and never exits, which is far harder to diagnose
  than a failed spawn; it now cleans up and throws.
- handle->hJob was assigned before LoadConptyDll, which can throw. A
  baton carrying a job but never reaching SetupExitCallback has nothing
  left to close it, so the assignment moved down beside hShell.
2026-08-21 21:55:37 -07:00
..