Neil d69897a3a0 fix(pty,remote): close the pty master fd leak and two remote-terminal defects
#8362: node-pty leaves the forkpty()/posix_openpt() master without FD_CLOEXEC,
so on Linux every later child of the process -- both later pty children and
plain child_process spawns -- inherits it and keeps the /dev/pts device alive.
Measured on Linux with stock node-pty 1.1.0: master fd flags 0404002
(cloexec=false), and 17 -> /dev/pts/ptmx present in both a later pty child's
/proc/self/fd and a later child_process child's. Extend the existing node-pty
patch with pty_cloexec() on both PtyFork spawn paths; after the patch the flags
read 02404002 (cloexec=true) and neither child sees the master. This covers the
app and terminal daemon only -- the SSH relay installs node-pty from npm on the
remote host, so it stays exposed (see the report).

#8414: the inspection queue's fire-and-forget `.finally()` chain re-raised a
rejecting inspection as a renderer-global unhandledrejection, which an
unreachable runtime produced on every cadence tick.

#9194: `tab_not_found` is the host's definitive "no such tab", but the close
path cleared the close intent for it exactly like a dropped connection, so a
host that keeps republishing the dead surface re-materialized the pane the user
just closed. Keep that intent and drop its TTL. Also route the banner's
"Remote terminal was closed." line through translate() so it stops mixing
English into a localized banner.