Files
tty7/src
l0ng-ai 237a6b8606 fix(remote): stop the server on machines that have no /proc, and show the install on the strip
Restarting the remote server timed out after ten seconds on every Mac and
BSD, with the old daemon still running and the new binary already sitting
next to it, unlaunched.

Both the probe that finds the running `tty7-server-*` and the command that
terminates it walked `/proc/[0-9]*` and read each `exe` symlink. There is no
`/proc` there. Two things then went wrong at once. zsh is the login shell on
macOS, and it aborts the whole command line when a glob matches nothing, so
even the trailing `true` never ran; and `cycle_daemon` discards the result of
the terminate, so a command that killed nothing was indistinguishable from
one that worked. `daemon_is_serving` then answered yes until the deadline.

Guard the glob behind `[ -d /proc ]` — unreached, it is never expanded, so
zsh has nothing to abort on — and fall back to `ps`, whose `comm` is the full
path on the BSDs. It cannot be the only branch: Linux truncates `comm` to 15
characters, one short of `tty7-server-c7p5`, which is why `/proc` stays the
first choice where it exists. `check_running_build` reads the same probe and
was equally blind on those machines; it can see now.

Separately, the install progress bar only ever existed inside the switcher.
Pressing Update Server from a parked workspace with no switcher open froze
the window for the length of the download and then produced a modal, with
nothing in between. The strip draws it too now — caption and bar from the
same source the switcher uses, and no button while an install is in flight,
since pressing it again would start a second one on top of the first.
2026-08-14 10:15:31 +08:00
..