Files
windmill/backend/windmill-queue
Ruben FiszelandClaude Opus 5.5 2c6bcc09c9 fix: refuse restarting a flow past an approval that was never granted (#11920)
Restarting a flow at the step right after an approval step copied the
approval step as completed, and the worker skips the gate at the restart
step, so a flow whose approval timed out or was disapproved could be
restarted past it without anyone approving. Restart resolution now
refuses a restart whose copied steps include an approval gate that never
opened, naming the step to restart from instead.

Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-21 17:48:58 +02:00
..