"tests": [
{
"input": {
"material": "Sulfuric Acid",
"quantity": 75,
"state": "liquid",
"location": "Lab-B42",
"transportMode": "road"
},
"output": {
"complianceRequirements": "Safety data sheets must accompany shipment",
"handlingProcedure": "Avoid contact with skin and eyes, neutralizing agents must be readily available",
"hazardClassification": "Class B - Corrosive",
"hazardLevel": "high",
"location": "Lab-B42",
"material": "Sulfuric Acid",
"permitRequired": "false",
"quantity": 75,
"recommendedStorageZone": "yellow-zone",
"reportingRequired": "false",
"requiredEquipment": "Chemical-resistant gloves, face shield, apron, boots",
"state": "liquid",
"storageLimit": 1000,
"transportMode": "road"
}
}
],
"nodes": [
{
"type": "inputNode",
"content": {
"schema": "{\n \"type\": \"object\",\n \"properties\": {\n \"material\": {\n \"type\": \"string\",\n \"description\": \"Name or code of hazardous material\"\n },\n \"quantity\": {\n \"type\": \"number\",\n \"description\": \"Quantity in kilograms\"\n },\n \"state\": {\n \"type\": \"string\",\n \"enum\": [\"solid\", \"liquid\", \"gas\"],\n \"description\": \"Physical state of the material\"\n },\n \"location\": {\n \"type\": \"string\",\n \"description\": \"Storage or handling location code\"\n },\n \"transportMode\": {\n \"type\": \"string\",\n \"enum\": [\"road\", \"rail\", \"air\", \"sea\", \"internal\"],\n \"description\": \"Mode of transportation if applicable\"\n }\n },\n \"required\": [\"material\", \"quantity\", \"state\"]\n}\n"
},
"id": "inputNode",
"name": "request",
"position": {
"x": 110,
"y": 114
}
},
{
"type": "decisionTableNode",
"content": {
"hitPolicy": "first",
"rules": [
{
"_id": "rule1",
"materialType": "some(['flammable', 'combustible'], contains($, #))",
"materialState": "'liquid', 'gas'",
"materialQuantity": "",
"classificationOutput": "'Class A - Flammable'",
"hazardLevelOutput": "'high'",
"storageZoneOutput": "'red-zone'"
},
{
"_id": "rule2",
"materialType": "some(['corrosive', 'acid', 'base'], contains($, #))",
"materialState": "",
"materialQuantity": "",
"classificationOutput": "'Class B - Corrosive'",
"hazardLevelOutput": "'high'",
"storageZoneOutput": "'yellow-zone'"
},
{
"_id": "rule3",
"materialType": "some(['toxic', 'poison'], contains($, #))",
"materialState": "",
"materialQuantity": "> 25",
"classificationOutput": "'Class C - Toxic'",
"hazardLevelOutput": "'high'",
"storageZoneOutput": "'green-zone'"
},
{
"_id": "rule4",
"materialType": "some(['toxic', 'poison'], contains($, #))",
"materialState": "",
"materialQuantity": "<= 25",
"classificationOutput": "'Class C - Toxic'",
"hazardLevelOutput": "'medium'",
"storageZoneOutput": "'green-zone'"
},
{
"_id": "rule5",
"materialType": "some(['radioactive'], contains($, #))",
"materialState": "",
"materialQuantity": "",
"classificationOutput": "'Class D - Radioactive'",
"hazardLevelOutput": "'extreme'",
"storageZoneOutput": "'black-zone'"
},
{
"_id": "rule6",
"materialType": "some(['explosive'], contains($, #))",
"materialState": "",
"materialQuantity": "",
"classificationOutput": "'Class E - Explosive'",
"hazardLevelOutput": "'extreme'",
"storageZoneOutput": "'black-zone'"
},
{
"_id": "rule7",
"materialType": "some(['oxidizer', 'oxidizing'], contains($, #))",
"materialState": "",
"materialQuantity": "",
"classificationOutput": "'Class F - Oxidizer'",
"hazardLevelOutput": "'high'",
"storageZoneOutput": "'blue-zone'"
},
{
"_id": "rule8",
"materialType": "",
"materialState": "",
"materialQuantity": "",
"classificationOutput": "'Unclassified'",
"hazardLevelOutput": "'low'",
"storageZoneOutput": "'grey-zone'"
}
],
"inputs": [
{
"id": "materialType",
"name": "Material Type",
"field": "lower(material)"
},
{
"id": "materialState",
"name": "State",
"field": "state"
},
{
"id": "materialQuantity",
"name": "Quantity (kg)",
"field": "quantity"
}
],
"outputs": [
{
"id": "classificationOutput",
"name": "Classification",
"field": "hazardClassification"
},
{
"id": "hazardLevelOutput",
"name": "Hazard Level",
"field": "hazardLevel"
},
{
"id": "storageZoneOutput",
"name": "Storage Zone",
"field": "recommendedStorageZone"
}
],
"passThrough": true,
"inputField": null,
"outputPath": null,
"executionMode": "single",
"passThorough": false
},
"id": "materialClassificationTable",
"name": "Material Classification",
"position": {
"x": 430,
"y": 114
}
},
{
"type": "decisionTableNode",
"content": {
"hitPolicy": "first",
"rules": [
{
"_id": "rule1",
"hazardClass": "'Class A - Flammable'",
"hazardLevel": "'high'",
"handlingEquipmentOutput": "'Fire-resistant gloves, face shield, flame-retardant clothing'",
"handlingProcedureOutput": "'Keep away from ignition sources, ensure proper ventilation, use non-sparking tools'",
"storageLimitOutput": "500"
},
{
"_id": "rule2",
"hazardClass": "'Class B - Corrosive'",
"hazardLevel": "'high'",
"handlingEquipmentOutput": "'Chemical-resistant gloves, face shield, apron, boots'",
"handlingProcedureOutput": "'Avoid contact with skin and eyes, neutralizing agents must be readily available'",
"storageLimitOutput": "1000"
},
{
"_id": "rule3",
"hazardClass": "'Class C - Toxic'",
"hazardLevel": "'high'",
"handlingEquipmentOutput": "'Chemical-resistant gloves, respirator, full protective suit'",
"handlingProcedureOutput": "'Use only in designated areas with proper ventilation, decontamination station required'",
"storageLimitOutput": "250"
},
{
"_id": "rule4",
"hazardClass": "'Class C - Toxic'",
"hazardLevel": "'medium'",
"handlingEquipmentOutput": "'Chemical-resistant gloves, safety goggles, lab coat'",
"handlingProcedureOutput": "'Use in well-ventilated area, wash hands thoroughly after handling'",
"storageLimitOutput": "500"
},
{
"_id": "rule5",
"hazardClass": "'Class D - Radioactive'",
"hazardLevel": "'extreme'",
"handlingEquipmentOutput": "'Radiation suit, dosimeter, remote handling tools'",
"handlingProcedureOutput": "'Special authorization required, time and distance protocols, radiation monitoring mandatory'",
"storageLimitOutput": "50"
},
{
"_id": "rule6",
"hazardClass": "'Class E - Explosive'",
"hazardLevel": "'extreme'",
"handlingEquipmentOutput": "'Anti-static clothing, specialized tools, blast shield'",
"handlingProcedureOutput": "'Expert personnel only, evacuation plan required, no electronic devices'",
"storageLimitOutput": "100"
},
{
"_id": "rule7",
"hazardClass": "'Class F - Oxidizer'",
"hazardLevel": "'high'",
"handlingEquipmentOutput": "'Chemical-resistant gloves, safety goggles, lab coat'",
"handlingProcedureOutput": "'Keep away from combustible materials, avoid contamination'",
"storageLimitOutput": "750"
},
{
"_id": "rule8",
"hazardClass": "'Unclassified'",
"hazardLevel": "'low'",
"handlingEquipmentOutput": "'Standard PPE (gloves, safety glasses)'",
"handlingProcedureOutput": "'Follow general laboratory safety procedures'",
"storageLimitOutput": "2000"
}
],
"inputs": [
{
"id": "hazardClass",
"name": "Hazard Classification",
"field": "hazardClassification"
},
{
"id": "hazardLevel",
"name": "Hazard Level",
"field": "hazardLevel"
}
],
"outputs": [
{
"id": "handlingEquipmentOutput",
"name": "Required Equipment",
"field": "requiredEquipment"
},
{
"id": "handlingProcedureOutput",
"name": "Handling Procedure",
"field": "handlingProcedure"
},
{
"id": "storageLimitOutput",
"name": "Storage Limit (kg)",
"field": "storageLimit"
}
],
"passThrough": true,
"inputField": null,
"outputPath": null,
"executionMode": "single"
},
"id": "handlingRequirementsTable",
"name": "Handling Requirements",
"position": {
"x": 750,
"y": 114
}
},
{
"type": "decisionTableNode",
"content": {
"hitPolicy": "first",
"rules": [
{
"_id": "rule1",
"hazardClass": "'Class A - Flammable', 'Class E - Explosive'",
"transportMode": "'air'",
"quantityCheck": "> 5",
"complianceOutput": "'Prohibited for air transport in this quantity'",
"permitRequiredOutput": "'true'",
"reportingRequiredOutput": "'true'"
},
{
"_id": "rule2",
"hazardClass": "'Class D - Radioactive'",
"transportMode": "'road', 'rail', 'air', 'sea'",
"quantityCheck": "",
"complianceOutput": "'Special NRC permit required, scheduled route mandatory'",
"permitRequiredOutput": "'true'",
"reportingRequiredOutput": "'true'"
},
{
"_id": "rule3",
"hazardClass": "'Class A - Flammable', 'Class B - Corrosive', 'Class C - Toxic', 'Class F - Oxidizer'",
"transportMode": "'road', 'rail', 'sea'",
"quantityCheck": "> 1000",
"complianceOutput": "'HAZMAT placards required, certified driver/handler only'",
"permitRequiredOutput": "'true'",
"reportingRequiredOutput": "'true'"
},
{
"_id": "rule4",
"hazardClass": "'Class A - Flammable', 'Class B - Corrosive', 'Class C - Toxic', 'Class F - Oxidizer'",
"transportMode": "'road', 'rail', 'sea'",
"quantityCheck": "> 100 and <= 1000",
"complianceOutput": "'HAZMAT placards required, safety data sheets must accompany shipment'",
"permitRequiredOutput": "'true'",
"reportingRequiredOutput": "'false'"
},
{
"_id": "rule5",
"hazardClass": "'Class A - Flammable', 'Class B - Corrosive', 'Class C - Toxic', 'Class F - Oxidizer'",
"transportMode": "'road', 'rail', 'sea'",
"quantityCheck": "<= 100",
"complianceOutput": "'Safety data sheets must accompany shipment'",
"permitRequiredOutput": "'false'",
"reportingRequiredOutput": "'false'"
},
{
"_id": "rule6",
"hazardClass": "'Class A - Flammable', 'Class B - Corrosive', 'Class C - Toxic', 'Class F - Oxidizer'",
"transportMode": "'internal'",
"quantityCheck": "",
"complianceOutput": "'Internal movement log required'",
"permitRequiredOutput": "'false'",
"reportingRequiredOutput": "'false'"
},
{
"_id": "rule7",
"hazardClass": "'Unclassified'",
"transportMode": "",
"quantityCheck": "",
"complianceOutput": "'Standard shipping procedures apply'",
"permitRequiredOutput": "'false'",
"reportingRequiredOutput": "'false'"
}
],
"inputs": [
{
"id": "hazardClass",
"name": "Hazard Classification",
"field": "hazardClassification"
},
{
"id": "transportMode",
"name": "Transport Mode",
"field": "transportMode"
},
{
"id": "quantityCheck",
"name": "Quantity (kg)",
"field": "quantity"
}
],
"outputs": [
{
"id": "complianceOutput",
"name": "Compliance Requirements",
"field": "complianceRequirements"
},
{
"id": "permitRequiredOutput",
"name": "Permit Required",
"field": "permitRequired"
},
{
"id": "reportingRequiredOutput",
"name": "Reporting Required",
"field": "reportingRequired"
}
],
"passThrough": true,
"inputField": null,
"outputPath": null,
"executionMode": "single"
},
"id": "regulatoryComplianceTable",
"name": "Regulatory Compliance",
"position": {
"x": 1070,
"y": 114
}
}
],
"edges": [
{
"id": "edge1",
"sourceId": "inputNode",
"targetId": "materialClassificationTable",
"type": "edge"
},
{
"id": "edge2",
"sourceId": "materialClassificationTable",
"targetId": "handlingRequirementsTable",
"type": "edge"
},
{
"id": "edge3",
"sourceId": "handlingRequirementsTable",
"targetId": "regulatoryComplianceTable",
"type": "edge"
}
]
}