The Electron probe carried the marker check, but it lives inside
probeElectronNativeModules, which returns early whenever the Electron package
binary is unusable. Covered by another path is not this path checks -- and the
defect this whole change closes was a gate that looked like it checked.

Reading the binary needs neither a loadable Electron nor an executable target
arch, so assert it after the rebuild, beside the windows-process-tree
assertion that exists for the same reason: this is the addon copied into the
packaged app. Absent warns (a cross-platform rebuild need not leave a win32
addon on this disk); present and unmarked is fatal.

The fixtures now write a real addon file, because the gate reads the binary it
was told about rather than trusting the exports. Verified against the two real
binaries measured on the Windows host: the pre-#19068 build fails this path,
the build from current patched source passes.